android smartphone xperia 8 lite (Sony)
Structured Review

Android Smartphone Xperia 8 Lite, supplied by Sony, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/android+smartphone/android+smartphone+xperia+8+lite/pmc12037849-95-19-25
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "Detection of sleep apnea using smartphone-embedded inertial measurement unit"
Article Title: Detection of sleep apnea using smartphone-embedded inertial measurement unit
Journal: Scientific Reports
doi: 10.1038/s41598-025-99801-3
Figure Legend Snippet: Respiratory amplitude (cyan line in ( A )) and frequency (dark green line in ( B )) extracted from IMU acceleration signal of an Android smartphone in a representative subject with sever sleep apnea during a PSG examination. In ( A ), the magenta and blue lines are the fast and slow envelopes (95th percentiles within 3-s and 30-s moving windows) of the respiratory amplitude, respectively. The black vertical lines with blue triangles are respiratory events (REs) detected as a > 30% reduction in the fast envelope from the slow envelope lasting 10–90 s. In ( B ), blue line is the upper envelope (95th percentile of 30-s moving window) of the respiratory frequency. Vertical black bars with green triangles are REs detected as > 30% reduction in the respiratory frequency from the envelope lasting 10–90 s. To avoid double counting of RE by both respiratory amplitude and frequency, the RE detection by the respiratory frequency was suppressed while the fast envelope of the respiratory amplitude was > 30% below the slow envelope. In ( C ), vertical red bars are RE (apnea and hypopnea episodes) detected by the simultaneous PSG.
Techniques Used:
Figure Legend Snippet: Respiratory amplitude (cyan line in ( A )) and frequency (dark green line in ( B )) extracted from the IMU acceleration signal of an Android smartphone during normal breathing in a subject undergoing a PSG examination. In ( A ), the magenta and blue lines, which show the fast and slow envelopes of the respiratory amplitude, respectively, overlap, and RE is not detected. ( B ) The blue line, which shows the upper envelope of the respiratory frequency, overlaps with the respiratory frequency itself, and RE is also not detected. RE is not detected in the simultaneous PSG ( C ).
Techniques Used:
Figure Legend Snippet: Relationships between apnea-hypopnea index (AHI) of polysomnography and the hourly frequency of RE-positive breaths obtained from smartphone IMU signals in the training ( A – C ) and test groups ( A ʹ– C ʹ); ( A , A ʹ) Amue Link, ( B , B ʹ) Xperia, and ( C , C ʹ) iPhone. r correlation coefficient, RE respiratory event, RMSE root mean squared error.
Techniques Used:
Figure Legend Snippet: Bland-Altman plots between polysomnographic AHI and smartphone-IMU REIs in the training ( A – C ) and test groups ( A ʹ– C ʹ); ( A , A ʹ) Amue Link, ( B , B ʹ) Xperia, and ( C , C ʹ) iPhone. Horizontal dotted lines indicate mean difference and dashed lines indicate the limits of agreement (± 1.96 SD) between two measures.
Techniques Used: